*NOTE: USUALLY 2 - 3 DAY LEAD TIME.

Fire-Lite MS2 Two-Zone Conventional Fire Alarm Control Panel
Fire-Lite MS2 Two-Zone Conventional Fire Alarm Control Panel
Item# FLA_MS-2-L8
$498.50

Product Description

Fire-Lite MS2 Two-Zone Conventional Fire Alarm Control Panel.

Model MS-2 suitable for local, central station and proprietary (protected premises).

The Fire Lite MS-2 2 zone Fire Alarm Control Panel (FACP) brings the latest in microprocessor technology to conventional fire controls. This Panel is compatible with the i³™ smoke detectors from System Sensor with drift compensation, maintenance alert, and freeze warning. Additionally the panel allows for automatic synchronization of audio/visual devices with three selections for manufacturer protocol. The Notification Appliance Circuit (NAC) protocol can silence audible devices while strobes continue to flash, using a single pair of wire.

The MS-2 is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices.

Refer to the Fire Lite Device Compatibility Document PN 15384 for a complete list of compatible devices.

MS-2 2 zone control panel Features and Benefits Two initiating zones compatible with 2- and 4-wire smoke detectors, one zone programmable for combo, supervisory and waterflow.

One Notification Appliance Circuit (NAC) with built-in horn/strobe synchronization for System Sensor®, Wheelock® or Gentex® with selectable silence.

3.0 amps total usable current.

Two Style B (Class B) Initiating Device Circuits (IDCs).

One Style Y (Class B) NAC.

24 VDC.

i³™ Technology features: Drift compensation automatically adjusts detector sensitivity and increases resistance to false alarms caused by dust accumulation. Maintenance Alert LEDs (per zone) warn of excessive dirt accumulation, preventing false alarms (meets NFPA 72 requirements). Detector sensitivity is automatically measured by the detector, which automatically adjusts its sensitivity back to the factory settings when it becomes more sensitive due to contaminants settling in the chamber. Wireless handheld sensitivity meter eliminates the need for voltmeters, magnets, and a physical connection to the detector. The reader displays sensitivity in terms of percent per foot obscuration and provides text status indication.

Supervisory LED (per zone) provides warning if a detector senses temperature approaching freezing.

Special test protocol and LED indication allows quick test of all detectors without need for a ladder.

Weight: 16 lbs.

S.L.A. batteries not included.